Installation of Soil Moisture Access Tubes in Gravels and Cobbles
Carpenter, C.D. (1972) Installation of Soil Moisture Access Tubes in Gravels and Cobbles. Soil Science. 113(6):453-455.
PDF
231.pdf Download (99kB) |
Abstract
A technique has been developed for installing
neutron probe access tubes in soils underlain
with saturated large gravels and cobbles. Conventional
augers and coring devices cannot be
used in this material because of the large-size
aggregates and the instability of the saturated
material. This method allows the access tubes
to be installed in locations that would otherwise
be eliminated from the study.
Item Type: | Article |
---|---|
NWISRL Publication Number: | 0231 |
Additional Information: | [Note] |
Subjects: | Soil > Soil water (soil moisture) Mass Import - autoclassified (may be erroneous) |
Depositing User: | Dan Stieneke |
Date Deposited: | 20 Nov 2010 21:51 |
Last Modified: | 16 Feb 2017 23:41 |
Item ID: | 223 |
URI: | https://eprints.nwisrl.ars.usda.gov/id/eprint/223 |