Skip to main content

Comparison of drop size and velocity measurements by a laser precipitation meter and low-speed photography for an agricultural sprinkler

King, B.A. and Winward, T.W. and Bjorneberg, D.L. (2014) Comparison of drop size and velocity measurements by a laser precipitation meter and low-speed photography for an agricultural sprinkler. Applied Engineering in Agriculture. 30(3):413-421.

[img] PDF
1500.pdf

Download (360kB)

Abstract

Kinetic energy of water droplets has a substantial effect on development of a soil surface seal and infiltration rate of bare soil. Methods for measuring sprinkler droplet size and velocity needed to calculate droplet kinetic energy have been developed and tested over the past 50 years, each with advantages, disadvantages, and limitations. Drop size and velocity of an impact sprinkler at three operating pressures and one nozzle size were measured using a laser precipitation meter and compared with published values obtained using a photographic method. Significant differences in cumulative volume drop size distributions derived from the two measurement methods were found, especially at the highest operating pressure. Significant differences in droplet velocities were found between measurement methods as well. Significant differences were attributed to differences in minimum drop sizes measured; 0.5mm for the photographic method versus 0.2 mm for the laser precipitation meter. The laser precipitation meter provided smaller cumulative volume drop size distributions compared to the photographic measurement method. The laser precipitation meter tended to provide greater drop velocities which were attributed to altitude differences at experimental sites. The difference in calculated droplet kinetic energy per unit drop volume based on drop and size velocity data from the laser precipitation meter and the photographic method ranged from +12.5 to -28%. The laser precipitation meter generally provided a lower estimate of sprinkler kinetic energy due to the measurement of a greater proportion of smaller drop sizes. Either method can be used to obtain drop size and velocity sprinkler drops needed to calculate sprinkler kinetic energy. The laser precipitation meter requires less skill and labor to measure drop size and velocity.

Item Type: Article
Subjects: Irrigation > Sprinkler irrigation
Depositing User: Users 6 not found.
Date Deposited: 25 Jul 2014 21:34
Last Modified: 25 Jul 2014 21:34
Item ID: 1543
URI: https://eprints.nwisrl.ars.usda.gov/id/eprint/1543