<> "The repository administrator has not yet configured an RDF license."^^ . <> . . . "Orifice Plates for Furrow Flow Measurement: Part II - Design and Field Use"^^ . "ORIFICES are potentially accurate furrow flow\ndevices. Flow measurement accuracy\ndecreases with head loss. Orifice head loss will increase\nupstream infiltration. Thus, the head loss range must be\nconstrained to maintain measurement accuracy. Design\nequations are developed for 3-hole orifice plates which\ngive a 23:1 flow range with a 5:1 head loss range. A\nportable differential point gauge can measure\nsubmerged flow head loss to the nearest millimeter."^^ . "1986" . . "29" . "1" . . "Transaction of the ASAE"^^ . . . . . . . . "Thomas J."^^ . "Trout"^^ . "Thomas J. Trout"^^ . . . . . . "Orifice Plates for Furrow Flow Measurement: Part II - Design and Field Use (PDF)"^^ . . . . . . . . . "571.pdf"^^ . . . "Orifice Plates for Furrow Flow Measurement: Part II - Design and Field Use (Other)"^^ . . . . . . "indexcodes.txt"^^ . . "HTML Summary of #453 \n\nOrifice Plates for Furrow Flow Measurement: Part II - Design and Field Use\n\n" . "text/html" . . . "Research methodology"@en . . . "Mass Import - autoclassified (may be erroneous)"@en . .